Property Condition Assessments: The Name That Has Set The Standard For over 27 Years.
Location
67 South Bedford, Burlington, MA
Total Buildings
1
Total Sqft:
176,866
PCA performed a Property Condition Assessment of 67 South Bedford in Burlington, Massachusetts, a four-story medical office building totaling approximately 176,886 square feet. The property was constructed in 1994 and sits on an 11.26-acre site. PCA’s scope addressed the building’s envelope, structure, mechanical and life-safety systems, and conveyances.
The engagement included architectural, structural, roofing, and mechanical/electrical/plumbing/limited fire-life-safety evaluations under ASTM E2018 protocols, alongside a vertical transportation assessment, a Level I and II Building Energy Performance Assessment, and a public records review. PCA documented observed conditions and quantified deferred maintenance and remaining-useful-life projections for the client’s reserve and capital planning. The vertical transportation assessment produced a reserve estimate for elevator replacement timing, while the energy performance work characterized building systems efficiency and the public records review supplemented field findings with documentation context. The consolidated findings gave the client a defensible basis for prioritizing near-term repairs and sizing reserves across the property’s principal systems.